If your pool has automatic dosing, these two probes are what tell the system how much product to add at any given moment. They work together, but they measure different things, and confusing what each one does is the most common mistake when talking about this subject.
Redox probe: it measures effectiveness, not quantity
Redox (oxidation-reduction potential) is measured in millivolts (mV), not in ppm. It doesn't tell you "how much chlorine there is", it tells you "how well that chlorine is disinfecting right now". It's the difference between quantity and effectiveness: you can have chlorine "within range" and still have poor disinfecting capacity if other factors (high pH, excess stabiliser) are neutralising it.
Redox (ORP)
It is a broad legal range, not an exact value, and the regulation only requires measuring it when the disinfectant isn't chlorine or bromine; with chlorine, the Redox probe is a control aid, not a requirement. As a practical guide, water is considered well disinfected when the Redox exceeds 650 mV.
pH probe: the one that makes the Redox reading meaningful
This measures exactly the same as any pH measurement, acidity or alkalinity, on the 0-14 scale. Its role here is to stop the Redox from "lying": with the pH out of range, chlorine loses part of its disinfecting power even though its quantity doesn't change, so the system needs to correct the pH first for the Redox reading to be reliable.
The real advantages of having both
- Dosing matched to actual conditions at the time, not to an estimated average
- Fewer day-to-day manual measurements
- Lower product consumption, the system only adds what is needed, not a fixed dose
The automatic dosing loop
The probes measure Redox and pH continuously, the controller compares the reading with the set-point values, and if a correction is needed it activates the dosing pump, which adds just enough product until the probes confirm that the water is back within range.
Why they don't completely replace manual testing
Although they automate day-to-day dosing, a poorly calibrated probe gives stable but incorrect readings, it is still worth checking against a manual reference measurement from time to time, especially if you notice something odd in the water that the probes aren't picking up.

